YLL/W Biomass/coal Thermal Oil Heater.
Rated power :1400~4600kw
Woking pressure : 0.9 Mpa
Fuel : coal
Certification : SGS , BV
This series boiler takes heat carrier oil as medium and uses the hot oil circulating pump force the medium to make Liquid
circulation; then the thermal energy will be transmitted to the devices and back to the furnace to be reheated. It is vertical
stype with chain grate , manpower-saving .
1. .high temperature with low pressure.
2. Safe, reliable, and environmental protection
3. reasonable structure, advanced technology.
4. manpower saving ,full automatic.
5. complete operating control and safety monitoring devices.
6. Saving energy and reducing consumption, compared with the steam heating it can save energy 1 to 1.5 times.
Model |
YLL-1400MA |
YLL-1800MA |
YLL-2400MA |
YLW-1400MA |
YLW-1800MA |
YLW-2400MA |
YLW-3500MA |
YLW-4200MA |
|||
Rated thermal power(kw) |
1400 |
1800 |
2400 |
1400 |
1800 |
2400 |
3500 |
4200 |
|||
Thermal efficiency(%) |
75 |
75 |
75 |
75 |
75 |
78 |
78 |
78 |
|||
Design pressure(Mpa) |
0.9 |
0.9 |
0.9 |
0.9 |
0.9 |
1.1 |
1.1 |
1.1 |
|||
Working pressure(Mpa) |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
0.8 |
0.8 |
0.8 |
|||
Working pressure(C) |
320 |
320 |
320 |
320 |
320 |
320 |
320 |
320 |
|||
Furnace capacity(m3/h) |
1.26 |
1.75 |
2.45 |
0.93 |
1.8 |
2.63 |
3.8 |
4.6 |
|||
Oil circulation(m3/h) |
80 |
100 |
150 |
80 |
11.5 |
155.7 |
188 |
225.64 |
|||
Connection diameter(DN) |
125 |
150 |
150 |
125 |
150 |
150 |
200 |
200 |
|||
Size |
L(mm) |
4830 |
5300 |
5800 |
6200 |
6360 |
6852 |
6324 |
7508 |
6935 |
7680 |
W(mm) |
2500 |
2620 |
2650 |
2300 |
2320 |
2500 |
2925 |
2925 |
3077 |
2885 |
|
H(mm) |
5500 |
5700 |
6000 |
3200 |
4420 |
5563 |
3020 |
1700 |
3394 |
2200 |
|
Weight (t) |
15.3 |
15.3 |
21 |
14.7 |
18.1 |
27.8 |
38 |